Evertz 5. 60. 0ACO- 2 Master Control Switchers. The 5. 60. 0ACO/ACO2 Automatic Changeovers are intended for use with two 5. MSC Master Clock / Sync Generators. The 5. 60. 0ACO/ACO2 system uses latching relays to ensure maximum reliability and minimal disruption in the event of any failure.
Evertz 5600msc manual, free download alvi nastaleeq urdu font, spectrasonics trilogy manual RSS. Main. Evertz 5600msc manual. Number 5600ACO 8 groups each consisting of two inputs and one output 5600ACO2 16 groups each consisting of two inputs and one output. Connector, bNC per IEC 60169-8 Amendment 2, inputs. The inputs to the 5600MSCs are internally split evertz by a 'Y' connector, incorrect sync word Power Autoranging 100-240V AC, to facilitate installation, type, color black. 5600ACO) provide an extra degree off reliability where dual redundant installations are required. The ACO provides relay changeover for the two LTC outputs, the six Sync pulse outputs, the 10 MHz reference output, and the GPI/O interface. A serial cable interconnecting the COM ports of the two 5600MSC units guarantees that the configuration and timing of the units are. Frame Manual 500ACO2-HD/SD Dual HD/SD SDI Auto Changeover Revision 1.5 500ACO2-HD/SD-1 1. OVERVIEW The Evertz 500ACO2-HD/SD dual SDI Auto Changeover is designed to provide extension to the 5600ACO.
Request 5601ACO2 Manual. Please provide the following information with your request. All fields are required. Name; Email; Phone; Company; Company Location; Evertz Sales Rep. Do you currently own this product? Yes: No: Submit Cancel. Solutions. MAGNUM Unified Facility Control; VUE Customizable User Interface; EQX High Density Routing; Live Production; Compression; Multi Screen and Web. Video Replay; Playout & Media Management. Master Control Switchers Evertz 5600ACO-2. NEW BCS Price: Click Here to Contact Us: Original MSRP: $5,500: Item #: MO808005N: Condition: NEW: Model Description: 5600ACO2 Automatic Changeover: Available Items. Master Control Switchers. NEW Evertz 5600ACO-2. Master select in Manual GPI control mode: Low: Selects Master A: High: Selects Master B: GPI2: Future use: Outputs; GPO1; Low: Master A is selected: High: Master B is selected: GPO2; Low: Master A & Master B differ or PSU failure: High. Evertz 5600ACO & 5600ACO2. Evertz Automatic Changeover. The 5600ACO/ACO2 Automatic Changeovers are intended for use with two 5600MSC Master Clock / Sync Generators. The 5600ACO/ACO2 system uses latching relays to ensure maximum reliability and minimal disruption in the event of any. detected, the 5600ACO2 circuitry will trigger and the entire bank of signals will be switched to the backup 5600MSC. In manual mode the changeover can be operated from a GPI or from the front panel switch.
The complete system provides the highest level of security for television station video and time synchronization systems. The 5. 60. 0ACO is a 1. RU device which is an ACO for a subset of the 5. MSC outputs. The 5.
ACO2 is a 2. RU ACO for all outputs of the 5. MSC. Two power supplies are included as a standard feature, to alleviate any single point of failure concerns. The front panel has three switches, recessed into the panel for added security. There is an AUTO / MANUAL switch, a GPI / FRONT PANEL switch and an A / B select switch for manual changeover. In automatic mode, all signals from both 5.
MSCs are monitored to detect any abnormal signals. For example if a level, pulse width, phase, time code error or other abnormality is detected, the 5. ACO2 circuitry will trigger and the entire bank of signals will be switched to the backup 5.
MSC. In manual mode the changeover can be operated from a GPI or from the front panel switch. LEDs provide status information as to the health of the two 5.
Evertz 5600ACO-2 Dual Automatic Changeover. The Evertz 5600ACO2 Automatic Changeover is intended for use with two 5600MSC Master Clock / Sync Generators. In manual mode the changeover can be operated from a GPI or from the front panel switch. LEDs provide status information as to the health of the two 5600MSCs, together with indication as to which one is active. Evertz 5600 Aco 2 Manual Leap Second App Note - 5600/5601 pdf Product Manual Manual. New 3Gb/s enabled The 2432TX-2 is used as extension of DVI over coax or fiber.
MSCs, together with indication as to which one is active. In addition two GPO outputs indicate which master is active and when the inputs from both masters are not the same. The 5. 60. 0ACO2 features selectable voting via Vista. LINKВ® for the autochangeover feature. Individual inputs may be selectively included or excluded in the voting process to drive autochangeover logic. Feature only available on 5. ACO2 model) Each 5.
MSC is equipped with 2 GPI inputs and 2 GPO outputs. To facilitate installation, these connections are brought through to a 2x. ACO. The outputs from the 5. MSCs are passed straight through the 5. ACO's. The inputs to the 5. MSCs are internally split by a 'Y' connector, to ensure that both 5. MSCs receive the same GPI contact closures.
In the event of a changeover occurrence, it is necessary that all outputs on one 5. MSC have the same timing as those on the other. Identical timing for both 5. MSCs is assured by locking both to the same frequency and phase source (e. GPS or by genlocking one 5.
MSC to the other). Identical phasing of the independent black outputs is assured by implementing the "Syncro" mode in the 5. MSCs. To use this mode, both 5. MSC communication ports are connected together using the link cable supplied with the 5. ACO. With both 5. MSCs operating in Syncro mode, timing adjustments made to one 5. MSC will be automatically applied to both.
The link cable is connected permanently, so that any system re- timing will be applied to both 5. MSC units. Features: Features. Three front panel switches select automatic, front panel or GPI activation of changeover Front panel switches are recessed to prevent accidental operation Front panel status LEDs show the health of each of the inputs Front panel status LEDs show the operational modes of the changeover Redundant power supply standard GPIO input/outputs Automatic changeover is a voting system based on which source has the most valid signals and that the good signals on the present master are also on the backup Vista.
LINKВ® capable offering remote monitoring via SNMP (using Vista. LINKВ® PRO) (5. 60. ACO2 only) Specifications: Specifications. Standard. SMPTE 1. M frame rate set by 5. MSCNumber of Inputs.
MSCNumber of Outputs. Connector. Input. Female DB9. Output. XLR type. Signal Level. Set in 5. 60. 0MSCType. Depends on signal connected from 5. MSC5. 60. 0ACODARS, bi- level or tri- level sync, color black,1.
MHz 5. 60. 0ACO2. HD SDI, SD SDI, Analog TG, AES, DARS, bi- level or tri- level sync, colour black, 1.
MHz, Word Clock Number. ACO8 groups each consisting of two inputs and one output.
ACO2. 16 groups each consisting of two inputs and one output. Connector. BNC per IEC 6. Amendment 2. Inputs. GPI1. Master select in Manual GPI control mode. Low. Selects Master AHigh.
Selects Master BGPI2. Future use. Outputs. GPO1. Low. Master A is selected. High. Master B is selected. GPO2. Low. Master A & Master B differ or PSU failure.
High. Master A & Master B have equivalent signals. Type. Inputs. Opto- isolated input with internal pull- up to +5. VOutputs. Normally closed relay to ground. K internal pull- up to +5.
V when relay is in active position. Connector. 4 pins plus 2 ground pins on 1.
Signal Level+5. V nominal. Inputs. 2 GPI inputs connected to both Master A and Master BOutputs. GPI outputs connected from Master A through AUXI/O A2 GPI outputs connected from Master B through AUXI/O BConnector. Signal Level. As specified in 5.
MSC manual. Notes• Changeover is a voting system based on which source has the most good signals and that the good signals on the current master are also present on the backup master. The input signals are considered good according to the following criteria: Video. Level below 7. 0 IRESync. H timing detect. 10. MHz. 3d. B level below 0. V p- p. DARSSync word error.
LTCLevel below 0. V p- p, Incorrect sync word. Power. Autoranging 1.
V AC, 5. 0/6. 0Hz 4. Watts. Configuration. Dual redundant supplies.
Fuse Rating. 25. 0V, 1. A, time delay. Safety. ETL Listed, Complies with EU Safety Directive. EMI/RFIComplies with FCC Part 1.
Class A, EU EMC Directive. Dimensions. 56. 00. ACO1. 9" W x 1. 7. H x 1. 8. 7. 5" D(4. W x 4. 5mm H x 4. D)5. 60. 0ACO2. 19" W x 3.
H x 1. 8. 7. 5" D(4. W x 9. 0mm H x 4. D)Weight. 56. 00.
ACO8lbs. (3. 5kg)5. ACO2. 16lbs. (7. 0kg).